Your local time Write to us

OT and ICS security

Visibility and segmentation for plant networks, designed around IEC 62443 zones and conduits.


01 · Build

What we build

A plant network often runs flat, with controllers that cannot be patched and vendors who connect from anywhere.

  • Passive inventory of PLCs, HMIs and drives, built from network traffic
  • Zeek and Suricata monitoring with Modbus, DNP3, S7comm and OPC UA parsers
  • Zone and conduit models, with firewall rules generated from them
  • Vendor remote access that is recorded and limited by time
  • Alerts sent to your SIEM, mapped to MITRE ATT&CK for ICS
  • Control evidence mapped to IEC 62443-3-3 system requirements

02 · Demo · sample data

Try it live.

A working sample with made-up data. It runs in your browser; nothing is sent anywhere.

Plant network reviewsample data
  • Plant 1, cells A-D, passive capture
  • Asset inventory
  • Unknown devices
  • Zone boundaries
  • PLC program changes
  • Vendor remote access

03 · Features

What it does well

  • 01

    Passive by default

    Discovery listens on a mirror port; nothing is sent to controllers on a live network.

  • 02

    Protocol awareness

    A write to a PLC register or a firmware download is seen as what it is, not as bytes.

  • 03

    Baseline of normal

    Which device talks to which, and how, is learnt per cell so a new conversation stands out.

  • 04

    Zones as data

    Zones and conduits live in one model, and firewall rules are generated and checked from it.

  • 05

    Recorded sessions

    Vendor access opens for an agreed window, through one gateway, and every session is recorded.

  • 06

    One alert queue

    Plant alerts reach the same SIEM and on-call rota as IT alerts, with plant context attached.

04 · FAQ

Questions

Will monitoring disturb our controllers?

No. Monitoring reads a copy of the traffic from a switch mirror port or a network tap and sends nothing to the plant network. Any active query of a device is done only with your engineers present, in a maintenance window agreed in writing.

We cannot patch our PLCs. What then?

Most plants cannot patch quickly, so the protection goes around the device: segmentation that limits who can reach it, monitoring that sees unusual writes or downloads, and access that is recorded. Patching is planned with the vendor and your maintenance windows.

Does this make us IEC 62443 certified?

No. Certification is issued by an accredited body. We design and build to the standard and map each control to the IEC 62443-3-3 requirement it supports, so your own assessment or an auditor has the evidence in one place.


Tell us what you need.

A person replies within 24 hours.